VTech C3500 SIP Classic Cordless 2-Line Accessory Handset User Manual

The VTech C3500 is a SIP cordless 2-line accessory handset designed for use with VTech SIP Classic Series 2-line bases, such as the S1310. It provides cordless mobility, charging functionality via compatible charging bases, and hospitality features for guest rooms. It supports DECT technology for registration and operation. It is part of a system that includes compatible bases and charging bases with power adapters and mounting brackets. Below are the key specifications, installation, operation, programming, and troubleshooting instructions for the C3500 handset.

1. Preparations 2. Description 3. Precautions 4. Specifications 5. Installation 6. Check Operation 7. Operating Features 8. Programming 9. Configuration 10. Troubleshooting

Preparations

Verify all parts are included: Cordless handset, rechargeable NiMH battery pack (BT264392/BT266342, 2.4V), screw (BY 1021), battery compartment cover. Install and charge handset battery before use. Ensure handset is registered to a compatible 2-line SIP base (e.g., S1310) before placing into charging base. Keep handset in the telephone base or charging base when not in use for optimal performance. Avoid placing near communication devices, heat sources, noise, dust, moisture, low temperatures, or vibrations.

CAUTIONS: Use only the supplied power adapter for charging base. To order replacements, call 1-888-907-2007. This product should be installed by a qualified technician. Save these instructions.

Handset Battery Installation: Gently lift the handset cover. Do not detach the speaker wires. Plug the battery connector securely into the socket inside the handset battery compartment. Place the battery with the label THIS SIDE UP facing up and the wires inside the battery compartment. Align all tabs on the handset cover against the corresponding grooves on the handset, then firmly push downward until all tabs lock. Secure with screw.

Description

The C3500 is a SIP cordless 2-line accessory handset designed for use with VTech SIP Classic Series 2-line bases and compatible charging bases. Handset layout: LINE 1 Key, CONF Key, LINE 2 Key, HOLD Key, OFF Key, FLASH Key, SPEAKER Key, REDIAL Key, LOW BATTERY LED, MUTE Key, MESSAGE WAITING LED, +/VOLUME/- Keys. Supports battery charging, automatic handset registration/deregistration via DECT. Unique hospitality features: Programmable speed dial keys for guest services, message waiting LED (steady/periodic high/low voltage pulse, reverse polarity, FSK, Siemens/Panasonic), energy-saving modes. Nominal effective range: Varies by environment; crystal-controlled PLL synthesizer with 10 channels, transmit frequency 1880-1900 MHz. Designed for guest room cordless mobility in 2-line SIP setups.

Applications: Hospitality SIP telephony; cordless 2-line accessory handset for hotel desk/wall setups.

Precautions

CAUTION! To prevent electrical shock or equipment damage, unplug before installation. Use only supplied power adapter.

WARNING! Follow safety precautions to reduce risk of fire, electric shock, or injury. Do not use near water; avoid rough handling. Do not open casing. Maintain 6-inch distance from medical devices like pacemakers. Wiring conforms to local codes. Avoid storms or gas leaks. Install by qualified technician only; connect only to host equipment. Use only specified adapter and battery (BT264392/BT266342, 2.4V Ni-MH); incorrect types risk explosion. Dispose batteries per local codes, not in fire. Keep metallic objects away from handset. Mount at less than 2 meters height. Operate in 0°C - 50°C, 5%-95% humidity non-condensing.

Specifications

Installation

For Compatible Charging Base: Choose area near outlet. Plug power adapter into base and outlet not controlled by switch. For wall mount: Reverse wall mount clip, insert mounting bracket into wall plate, position eyelets against studs, slide down to lock.

For C3500 Handset: Install battery as in Preparations. Place on charging base or main base for charging/registration. Automatic registration on first placement to compatible 2-line SIP base (e.g., S1310): MESSAGE WAITING LED flashes once, 3 rising beeps. Deregistration: When idle, press MENU > Deregister Handset > Select > OK. To register to another base, place on new base for automatic process. Ensure installation height under 2 meters.

CAUTIONS: Use only supplied cords; call 1-888-907-2007 for replacements. Risk of explosion with wrong battery type.

Check Operation

Place C3500 handset on charging base; CHARGE LED should turn on (full charge in 16 hours). For system check: Ensure power secure on base. Press LINE 1 or LINE 2 on handset for dial tone, then end call. Verify registration by placement (LED flashes, beeps). Test incoming call: Handset rings, MESSAGE WAITING LED flashes. For range, test within effective range; handset beeps if out. If no dial tone, unplug/replug power 15 seconds. In hospitality, test speed dials and conference.

Operating Features

Hospitality: Speed dial for services; energy-saving mode; 2-line operation.

Programming

Program via compatible base: Press recessed PROGRAM key. Speed dial: Up to 10 keys; press PROGRAM, select key, enter number (up to 32 digits). Flash duration: 3 options via PROGRAM. Voicemail detection: FSK and voltage methods via PROGRAM. Energy-saving: On idle handset, press *331734# then HOLD (3 beeps), place in charger. Battery replacement: Pry open cover, remove screw, unplug old, install new BT266342, secure. Changes effective upon confirmation.

Hospitality: Program speed dials for guest services; easy deregistration for room turnover.

Configuration

Default settings indicated by asterisks (*). Adjustments via handset/base menu.

SettingDefaultOptionsComments
Listening VolumeMedium (4*)1-8During call: VOLUME +/-; resets per call
Speakerphone VolumeMedium (4*)1-8During call: VOLUME +/-
Ringer VolumeMedium (2*)Off, Low, Medium, HighIdle: VOLUME +/-
Ringer ToneTone 1*Tone 1,2,3MENU > Ringer Tone
RF Transmission PowerMiddle (2*)Low (1), Middle (2), High (3)For range adjustment; coverage varies
Flash Duration600ms (3*)100ms (1), 300ms (2), 600ms (3)MENU > Flash

Admin Access: Menu-driven for adjustments; voicemail settings, speed dial, SIP configurations.

Troubleshooting

SymptomPossible CauseCorrective Action
Handset does not ringRinger off; not registered.Adjust ringer VOLUME; re-register handset to base.
Handset does not workLow battery; out of range.Charge 16 hours; move closer to base; check registration.
CHARGE LED offMisalignment; power issue.Reposition; check adapter; unplug/replug 15s.
No dial tone on LINE 1/2Base connection; range.Verify base power/line; move closer; re-register.
Poor audio/InterferenceDistance; environmental.Reduce distance; adjust RF power; avoid interference sources.
Low batteryDepleted; old battery.Charge 16 hours; replace with BT266342 if needed.

Care: Wipe with soft damp cloth; avoid liquids. Dispose battery properly via RBRC®. For service: www.vtechhotelphones.com or 1-888-907-2007.

VTech C3500 SIP Classic Cordless 2-Line Accessory Handset Manual© - All Rights Reserved 2025